800-353-9425

PROJECT SPOTLIGHT: Eliminating Below-Grade Fall Hazards at Florida Power & Light

FLS designed, fabricated, and installed three custom galvanized Kee Guard parapet railing systems to safeguard utility maintenance personnel around high-voltage transformer oil containment basins in Parrish, Florida.

Talk to an ExpertTalk to an Expert

Or, give us a call: 1-800-353-9425

Published on: October 21, 2026


Engineered Perimeter Protection for Utility-Scale Energy Storage Containment Basins

Hazard: Daily service around three at-grade oil containment basins (pits) measuring 47 feet by 33 feet and 2 feet 6 inches deep, creating unprotected interior drop-offs and high-frequency trip-and-fall exposure for utility maintenance technicians during high-voltage transformer upkeep.

Solution: Turnkey implementation of three Kee Guard galvanized parapet railing enclosures utilizing structural Kee Klamp modular fittings, anchored internally along the vertical concrete pit walls and integrated into existing stairway access infrastructure.

Benefits: 100 percent passive fall protection eliminating personal fall arrest harness reliance, full structural containment wall integrity preservation, zero interference with EPA SPCC oil collection capacity, and verified OSHA 1910 walking-working surface compliance.


The Challenge: Mitigating High-Exposure Edge Hazards in Utility Substation Infrastructure

Florida Power & Light (FPL), the principal subsidiary of NextEra Energy Inc., operates the Manatee Energy Storage Center in Parrish, Florida. Spanning 40 acres with 132 energy storage containers, this 409 MW / 900 MWh installation represents the world’s largest solar-powered battery system. Maintaining continuous transmission uptime requires utility crews to perform regular inspections, diagnostic testing, and routine maintenance around large outdoor substation transformers responsible for stepping down high transmission voltages to distribution levels below 10,000 volts.

Because oil-insulated electrical equipment is subject to strict Environmental Protection Agency (EPA) Spill Prevention, Control, and Countermeasure (SPCC) mandates, each transformer foundation is encircled by a concrete oil containment basin measuring 47 feet by 33 feet. Although the 2-foot-6-inch basin depth falls below standard OSHA 4-foot general industry fall protection thresholds, the basins are set flush at grade. Maintenance teams traversing the transformer yards were subjected to high-frequency exposure along unbarricaded vertical concrete drop-offs. Given the presence of oil, industrial washdowns, and energized high-voltage equipment, a trip or slip into an open pit carried a significant risk of impact injury and operational disruption. FPL safety leadership determined that proactive, passive barrier protection was required to eliminate this hazard entirely.

The Process: Collaborative Engineering, Material Direct-Fastening, and Substation Execution

In November 2021, FPL contacted Flexible Lifeline Systems to identify an engineered fall protection solution capable of securing the perimeter of all three containment basins without compromising environmental containment walls. FLS project engineers evaluated client-supplied foundation and civil drawings to assess concrete thickness, reinforcement layouts, and boundary clearances around the transformer pads. By December 2021, FLS delivered comprehensive CAD submittals and a proposal that met client design approvals in February 2022.

Executing fall protection installations in an active, utility-scale power storage facility demands precise field logistics and strict adherence to electrical clearance protocols. In March 2022, FLS staged all galvanized structural pipe, Kee Klamp modular fittings, hammer drills, and powder-actuated direct fastening systems on-site. Field installation commenced in April 2022, during which FLS installation specialists mounted the modular system along the inside face of the concrete containment parapets. This eliminated the risk of concrete spalling on top edges and tied seamlessly into existing metal access stairways, delivering complete turnkey installation on budget and on schedule.

The Solution: Modular Galvanized Kee Guard Parapet Railing Systems

FLS engineered, supplied, and installed a comprehensive turnkey passive perimeter barrier solution tailored directly to the geometry of the Manatee Energy Storage Center containment structures.

  • Segmented Perimeter Footprint: Three fully enclosed modular safety rail perimeters enclosing three 47-foot by 33-foot concrete containment pits, providing complete perimeter shielding around all transformer secondary containment areas.
  • Internal Wall-Mount Baseplates: Heavy-duty Kee Klamp side-mount flange fittings anchored directly into the interior vertical concrete pit walls using mechanical anchors and direct-fastening hardware, eliminating top-of-wall penetration and protecting the containment barrier from moisture ingress.
  • Continuous Multi-Worker Passive Protection: Non-penetrating top rails and midrails engineered to protect an unlimited number of service technicians simultaneously without requiring lanyards, harnesses, or active system training.
  • Modular Structural Load Integrity: High-strength, hot-dip galvanized steel pipe and set-screw Kee Klamp connections engineered to withstand OSHA 1910.29 requirements of a 200-pound point load applied in any outward or downward direction along the top rail.

Summary: Delivering Zero-Maintenance Passive Safety for Critical Utility Assets

The completed KeeGuard installation transformed three open industrial containment pits into fully safeguarded maintenance zones. By opting for an engineered passive guardrail barrier over administrative controls or active fall restraint gear, FPL eliminated fall hazards at the source. Utility technicians now conduct transformer diagnostics and environmental inspections with uninhibited mobility, total perimeter security, and full regulatory compliance.

Beyond structural durability, FLS provides ongoing lifecycle reliability for utility and industrial facilities nationwide. Through structured annual safety audits, visual system inspections, hardware tension verifications, and engineering recertifications, Flexible Lifeline Systems guarantees that every fall prevention asset remains fully compliant and structurally sound throughout its operational lifecycle.

Ready to enhance safety and efficiency at your facility? Contact Flexible Lifeline Systems for a comprehensive safety audit and let our team of experts help you find the perfect solution for your work at height.