 A Qualified Person: such as a structural engineer: must verify the roof can handle the concentrated 600+ lb load of the assembly. This is especially critical for older buildings or lightweight roof decks.
Read More

Posted on February 5, 2026

After an impact: the system must be immediately removed from service. The rubber suction cups and the galvanized steel components must be inspected by a Qualified Person to ensure no sliding or structural deformation occurred. 
Read More

Posted on February 5, 2026

 High UV exposure can cause rubber to become brittle over time. We use specialized: bonded rubber designed for harsh environments: but the weights should be inspected annually for cracking that could reduce friction. 
Read More

Posted on February 5, 2026

These anchors are engineered for use with lanyards that have a maximum arresting force of 900 lbs. Using a lanyard that exerts higher forces may cause the anchor to slide across the roof surface during […]
Read More

Posted on February 5, 2026

 Yes: but the stone chipping or gravel must be brushed back so the rubber weights make direct: 100% contact with the roof membrane or concrete to ensure maximum suction. 
Read More

Posted on February 5, 2026

Handles ensure that workers can transport the 56 lb components safely without dropping them on their feet or the roof membrane: preventing injuries and accidental damage during the setup process. 